Manufacturer bulletin explained
For specified early 2017 Pacifica PHEVs, FCA documented a situation where a vehicle-side isolation fault associated with P0AA6 could be followed by an incorrectly set battery-side P1E1B at key-off and a no-start condition. The publication included battery-control software improvements and related controller requirements.
A second code does not erase the first fault
The important distinction is between the original isolation concern and the way software could report a subsequent condition. A software-related reporting issue does not make an actual high-voltage isolation fault harmless. Both the fault evidence and the applicable software requirements need attention.
This example is limited to the bulletin’s build and equipment scope. It cannot be applied to every Pacifica or used to declare a traction battery healthy from the code pair alone.
Keep the order of events
Record whether the warning appeared while driving, charging or switching off, and when the vehicle stopped reaching READY. Preserve the first scan as well as later reports. Clearing faults between those stages can remove the sequence that makes the complaint understandable.
Include any previous programming and the installed controller software identities. Where a manufacturer procedure has interdependent updates, completing one controller is not evidence that the whole process has been completed.
Arrange the correct assessment
Do not bypass isolation monitoring or repeatedly clear the no-start condition to keep using the vehicle. AXION can discuss the electronic diagnostic scope and the evidence needed. The linked North American bulletin is technical background, not a statement of current UK recall or warranty coverage for an imported vehicle.
Source material
FCA bulletin 08-043-17 Revision A, June 2017
Discuss the next step
EV and hybrid assessment. Send your vehicle details and symptoms or call 07440 134303. Didcot workshop appointments and suitable UK postal or remote work are agreed before booking or dispatch.