Diagnostic guide
A manufacturer software bulletin may also contain conditions that require hardware repair. Reading only its headline can produce the wrong conclusion for an EV that will not enter READY mode.
Keep the active faults separate
Dodge bulletin 08-311-26, dated August 2026, covers listed North American 2024–2025 electric Charger applications. It includes P1CDB among several complaints addressed by powertrain software changes, but also identifies active battery-controller faults that require a different repair branch.
This is a model-specific example, not a claim that an update cures every wake-up, contactor or isolation fault. It does not apply to a combustion-engine Charger or establish UK campaign eligibility for an imported vehicle.
Ask what remains present now
The useful next evidence is the complete scan with fault status, controller identities and previous update history. A historical entry after an event differs from a currently active condition that the guided diagnostic process treats as a hardware problem.
Do not repeatedly clear the report or attempt to force READY mode. Preserve the original evidence and follow any stop or shutdown warnings. High-voltage contactors and protection circuits must not be bypassed to determine whether the car can move.
Programming must have an outcome check
AXION can review supported electronics enquiries and help identify the information required for the appropriate repair route. If software work is applicable, retain the before-and-after protocol and verify the original symptom. If the evidence requires hardware assessment, a successful download does not remove that requirement. Current manufacturer guidance and the exact vehicle configuration must govern the decision; the source is a technical reference rather than a guaranteed repair offer.
Source material
Dodge TSB 08-311-26 manufacturer text reproduced by OEMDTC
Discuss the next step
EV and hybrid assessment. Send your vehicle details and symptoms or call 07440 134303. Didcot workshop appointments and suitable UK postal or remote work are agreed before booking or dispatch.