Fault-code guide
When every parking sensor appears dead, the controller is not the only possibility. One failed load can affect a supply shared by several sensors.
The shared-supply fault
Ross-Tech describes 01549 as a parking-sensor supply short to earth. Its note explains that one faulty sensor can reduce the reported supply voltage and outlines controlled isolation of sensor branches to locate the affected area. Wiring and protection remain part of the checks.
Narrow the branch before replacing parts
The useful assessment compares the supply and system response as the relevant branches are isolated using the correct procedure. A supply returning when a branch is removed implicates that branch, but the sensor and its wiring still need distinguishing.
A voltage reading may also depend on the controller’s protective state. Follow the required restart or test conditions rather than interpreting a stale value after a connector change. Do not connect sensors while circuits are powered unless the procedure specifically permits it.
Keep the whole-system result
Tell AXION whether the failure followed a bumper impact, repaint or water exposure, and provide the full scan. A new controller connected to the same shorted load may show the same fault. Verification should confirm a stable supply with all required sensors connected and correct operation of each channel. Clearing the fault with a damaged sensor left unplugged is not a completed parking-system repair. The final record should identify the failed branch, what was repaired and how the intended warning functions were checked.
Source material
Ross-Tech 01549 diagnostic reference
Discuss the next step
Body-electronics assessment. Send your vehicle details and symptoms or call 07440 134303. Didcot workshop appointments and suitable UK postal or remote work are agreed before booking or dispatch.