Fault-code guide
A powered seat can move without providing reliable position feedback. The distinction matters when movement works but memory recall or a particular adjustment behaves incorrectly.
The two sensor references
Ross-Tech associates 02327 and 02328 with open-circuit faults in the G438 and G439 height-adjustment position-sensor circuits. Its checks include protection, wiring, connectors and the sensors. The front/rear wording must be matched to the seat mechanism in the actual repair information.
Identify the failed adjustment precisely
Record which seat and which movement are affected. Compare the relevant position reading with the physical movement under the appropriate diagnostic procedure. A value that remains fixed while the mechanism moves points towards a different problem from a motor that cannot move the mechanism.
Recent seat removal, trim work or objects trapped in the travel area are useful history. Wiring beneath seats can include restraint circuits as well as comfort functions, so connector colours or nearby wires must not be used as a substitute for the diagram.
Verify movement and position separately
Send AXION the scan, seat equipment details and a clear description of the faulty function. Keep the travel area clear and do not place hands under an operating seat. Verification should show a credible position signal through the relevant travel and the intended memory behaviour where fitted. A single successful movement does not establish that the feedback remains reliable. Do not replace a complete seat controller before the affected sensor circuit and its electrical prerequisites have been assessed.
Source material
Ross-Tech 02327 diagnostic reference · Ross-Tech 02328 diagnostic reference
Discuss the next step
Body-electronics assessment. Send your vehicle details and symptoms or call 07440 134303. Didcot workshop appointments and suitable UK postal or remote work are agreed before booking or dispatch.