Fault-code guide
An airbag warning and an air-conditioning fault may have a common electrical cause. Reading only the restraint controller can hide that connection and lead to an unnecessary seat-module replacement.
The Golf Mk6 shared-supply example
Ross-Tech describes B1022 electrical-failure and not-configured entries for the J706 seat-occupancy controller. On Golf Mk6-based vehicles with AirbagVW10G, it specifically recommends checking for a simultaneous G65 pressure-sensor fault such as B10AE in the HVAC controller because the circuits can share a fuse.
Read both systems before configuration work
Save a complete scan and confirm the actual wiring arrangement for the vehicle. If both faults appeared together, the next useful assessment is the shared supply and the reason it failed. Replacing a fuse without finding the overload or damaged branch can leave the original problem unresolved.
If supply and wiring are correct but the occupancy system remains unconfigured, follow the applicable configuration and calibration procedure. The text not configured is not permission to start programming while an electrical fault is still active.
Keep occupancy detection functional
Do not code out the seat sensor or substitute an emulator to extinguish the warning. Send AXION the controller identities, full fault details and recent seat or HVAC work. Verification should establish correct operation of both affected systems and all required restraint checks. A repaired pressure-sensor circuit may explain the shared fuse failure, but it does not by itself prove correct passenger classification.
Source material
Ross-Tech B1022 diagnostic reference
Discuss the next step
SRS electronics assessment. Send your vehicle details and symptoms or call 07440 134303. Didcot workshop appointments and suitable UK postal or remote work are agreed before booking or dispatch.