SENT data nibbles combined in the wrong order
A digital sensor can produce an orderly waveform yet display an impossible measurement when its data fields are assembled incorrectly.
Evidence-led diagnosis of intermittent faults, communication failures and problems affecting multiple vehicle electronics systems.
A digital sensor can produce an orderly waveform yet display an impossible measurement when its data fields are assembled incorrectly.
On a conventional network with two 120-ohm terminations, adding a third changes the total load.
An extra CAN termination resistor can create a new fault Read More »
A receiver can control how many consecutive frames are sent before another flow-control exchange.
ISO-TP block size can explain pauses in a diagnostic transfer Read More »
A pressure reading may look believable while the sensor also reports a status problem.
SENT status information when the pressure value still looks reasonable Read More »
Ringing is a brief oscillation around a signal transition.
CAN ringing after a harness joint or connector repair Read More »
A sender may wait for flow-control information before continuing a multi-frame transfer.
ISO-TP flow-control timeouts during a module data read Read More »
A CAN trace can show both wires shifting together while their difference remains recognisable.
CAN common-mode voltage when both signal wires move together Read More »
A long diagnostic reply can be split across several CAN frames.
An ISO-TP first frame without the rest of the diagnostic reply Read More »
A sensor can send a fast-changing measurement alongside slower identification or status information on the same signal wire.
SENT fast data and slow data can describe different sensor information Read More »
A microcontroller needs its supply to remain within the conditions specified for reliable operation.
Brownout resets and an ECU that restarts when its supply dips Read More »